D. Wu, X. Lan, G. Litscher, Y.L. Zhao, Y.Q. Wu, R.J. Dai, K. Cao, Y. Wang, L.Q. Chen
Lasers in Medical Science, 39(1):29, 2024
To investigate the efficacy of laser acupuncture and photobiomodulation therapy in alleviating symptoms among patients diagnosed with Bell's palsy with duration of greater than 8 weeks. The randomized controlled trial has been performed from May 2021 to April 2023. Patients were eligible who had Bell's palsy with duration of greater than 8 weeks on out-patient Department of Otorhinolaryngology in Beijing Tongren Hospital. The laser acupuncture group received class IV laser treatment for 3 times per weeks, a total of 72 times. The control group received the same treatment procedure except the laser parameter. The primary outcome measures comprised House-Brackmann facial nerve grading system and electroneurography. Secondary outcome measures comprised Sunnybrook facial grading system, electromyography, and the blink reflex. A total of 84 participants were included (42 control group, 42 laser acupuncture group). After treatment, House-Brackmann facial nerve grading system (OR, 0.11; 95% CI, 0.04-0.30; P < 0.001), and the pathologic numbers of electroneuronography were statistically different between the laser acupuncture group and control group, including orbicularis oculi (OR,0.08; 95% CI, 0.02-0.21; P < 0.001), Frontalis muscle (OR,0.14; 95% CI, 0.05-0.39; P < 0.001), Orbicularis oris (OR,0.13; 95% CI, 0.04-0.36; P < 0.001), Ala nasi muscle (OR,0.06; 95% CI, 0.02-0.18; P < 0.001). In secondary outcomes, Sunnybrook facial grading system, has significant difference between the two groups (20.26; 95% CI, 14.69 to 25.83; P < 0.01). Latency by ENoG, include orbicularis oculi (-0.61; 95% CI, -0.43 to -0.09; P < 0.001), frontalis muscle (-0.12; 95% CI, -0.21 to -0.03; P < 0.01), orbicularis oris (-0.28; 95% CI, -0.41 to -0.16; P < 0.001), and ala nasi muscle (-0.26; 95% CI, -0.38 to -0.16; P < 0.001). All amplitudes of MUAPs and durations by electromyography (EMG) showed statistically significant differences compared with the control group after treatment. For the frontalis muscle, the amplitude of MUAPs was -64.23 (95% CI, -80.89 to -47.56; P < 0.001) and duration was -1.18 (95% CI, -1.49 to -0.87; P < 0.001). For orbicularis oris, amplitude of MUAPs was -29.82 (95% CI, -55.03 to -4.62; P = 0.02) and duration was -0.57 (95% CI, -0.94 to -0.20; P < 0.001). For depressor angulli oris, amplitude of MUAPs was -47.06 (95% CI, -62.15 to -31.97; P < 0.001) and duration was -2.21 (95% CI, -2.69 to -1.72; P < 0.001). Blink reflex, including R1 (OR, 0.03; 95% CI, 0.01-0.16; P < .001), R2 (OR, 0.04; 95% CI, 0.004-0.29; P < .001), and R2 latency differences (OR, 0.15; 95% CI, 0.05-0.51; P < .001), have significant difference between the two groups, respectively. The findings suggest that laser acupuncture relieve symptoms for patients with Bell's palsy with a duration of greater than 8 weeks.
L'accesso alla visualizzazione dei prodotti e al materiale informativo è riservato agli operatori del settore in ottemperanza alla legislazione vigente. ASA richiede di qualificarsi come operatore del settore per procedere con la navigazione.
Decreto Legislativo 24 febbraio 1997, n°46 Articolo 21
1. E' vietata la pubblicità verso il pubblico dei dispositivi che, secondo disposizioni adottate con decreto del Ministro della Sanità, possono essere venduti soltanto su prescrizione medica o essere impiegati eventualmente con l'assistenza di un medico o di altro professionista sanitario.
2. La pubblicità presso il pubblico dei dispositivi diversi da quelli di cui al comma 1 è soggetta ad autorizzazione del Ministero della Sanità. Sulle domande di autorizzazione esprime parere la Commissione di esperti prevista dall'articolo 6, comma 3, del decreto legislativo
30 dicembre 1992, n. 541, che a tal fine è integrata da un rappresentante del Dipartimento del Ministero della Sanità competente in materia di dispositivi medici e da uno del Ministero dell'Industria, del commercio e dell'artigianato.
Some of the contents of this website cannot be disclosed in the USA and its territories and possesions, for regulatory reasons. If you are a US resident, please click on the button here below and access ASA's distributor website for North America.